کدهای خطای HP DesignJet 1055CM
- آبان 26, 1395
|
| Code | Description |
| 080001 | PostScript Error. |
| 09xxxx | EIO Accessories (EIO Card/Hard Disk Drive) Error. |
| 0A0000 | The Air Pressure is below the minimum requirement. |
| 0A0010 | Problem in Pressurizing the Air System. |
| 0A0020 | Error in Calibrating the APS Sensor. |
| 0A0030 | Problem in Depressurizing Air System. |
| 0A0040 | Ink Tubes Initialization Failure Due to Low Air Pressure. |
| 0A0050 | The Printer has detected a leak in the Tubes System before the life of the System. |
| 0A0060 | The Printer has detected a leak in the Tubes System after the life of the System. |
| 0A0070 | The Backup EEROM contents stored in the Tubes System are not consistent with the ones required by the firmware. |
| 0B0000 | Bad Ambient Temperature measured. |
| 0B0001 | Bad Humidity read. |
| 0B0002 | Bad IDS pressure read. |
| 0B0003 | ADC0 Internal channels check Failure. |
| 0B0004 | Unable to detect Pump. |
| 0B0005 | Unable to detect Valve. |
| 0B0006 | The Trailing Cable has been incorrectly connected OR the fuse in the Electronics Module has been burned. |
| 0B0007 | Unable to detect Vacuum Fan. |
| 0B0008 | Unable to detect Cooling Fan. |
| Code | Description |
| 0B0009 | Unable to detect Aerosol Fan (Included on the Right Cover). |
| 0B000A | Primer Shutdown Error. |
| 0B000B | Pump or Pressure Sensor not working. |
| 0B000C | Serial Device ADC test failure |
| 0B000D | 24 V source test failure. |
| 0C0030 | Bad Drop Detector. |
| 0C0032 | Drop Detector not Calibrated for all Printheads. |
| 0C1000 | Primer not Calibrated. |
| 0C1001 | Primer Shutdown Error. |