کدهای خطای HP DesignJet 2000CP
- آبان 26, 1395
| Code | Description |
| 0000D8 | Library Error. |
| 010020 | The Checksum read on the Flash SIMM is incorrect. |
| 010021 | The baseDRAM or theRAM SIMM tests failed. |
| 010022 | The SWATH RAM test failed. |
| 010023 | A fuse on the Main PCA has blown. |
| 010024 | Problem initializingthe encoder pulse generator. |
| 010030 | One of the two interconnect boards not detected. |
| 010031 | The Printhead Primitive Driver ASIC Test Failed. |
| 010032 | Fan Test Failed -Current not detected in one or bothfans. Error data (XX): 1 -Electronics Module fan not running. 2 -Service station fan not running. 3 -Bothfans not running. 10 -Electronics Module fan is short-circuited. 20 -Service Station fan is short-circuited. 30 -Bothfans are short-circuited. 12 -Service Station fan is not running and the Electronics Module fan is short-circuited. 21 -Electronics Module fan is not running and the Service Station fan is short-circuited. |
| 010033 | The DC Motor Driver ASIC Test Failed. |
| 010034 | One of the DC Motors has failed. Error data: 00010000 -Y-axis Motor Failed. 00020000 -X-axis Motor Failed. 00030000 -Both DC Motors Failed. |
| 010035 | One of the Stepper Motors has failed. Error data (oXABCDEF): If the value of each letter is o, then the component is OK. If the value of each letter is different from 0 then the component has failed. X -Electronics signal failed (ignore other values). A -Elevator Stepper Motor Failed. B -Refill Stepper Motor Failed. C -Primer Stepper Motor Failed. D -Service station (Z-axis) Stepper Motor Failed. E -Service station (X-axis) Stepper Motor Failed. F -Bail Stepper Motor Failed. |
| 010036 | ADC Test Failure in the Main PCA A short circuit in the Y/X-axis or ANY stepper motor. This short circuit is causing some of the fuses in the Electronics Module to burn. Error data: 00000800 -Problem with the Y-axis. 00001000 -Problem with the X-axis. |
| 010037 | ADC Test Failure in the Carriage PCA. |
| 010038 | A Printhead voltage could not be set -Main PCA Failure. |
| 010039 | A Printhead voltage could not be set -Carriage PCA Failure |
| 010040 | The Ambient Temperature measured is out of the normal range. |
| 010042 | The status of one of the opticalsensors is not stable when it should be. Error data (X): 0 -Problem with the Media Sensor. 1 -Problem with the Pinch-arm Sensor. 2 -Problem with the Refill Assembly Sensor. 3 -Problem with the Elevator Sensor. 4 -Problem with the Service Station Sensor. 5 -Problem with the Primer Sensor. |
| 010043 | Problem with theCarriageBoard. |
|
|